• IMAC Ni-NTA 6FF Prepacked Column
  • IMAC Ni-NTA 6FF Prepacked Column

IMAC Ni-NTA 6FF Prepacked Column

No.SA036C11, SA036C51, SA036C15, SA036C55
IMAC Ni-NTA 6FF Prepacked Column is one of a range of prepacked, ready-to-use columns for affinity chromatography. 
$159.00
Volume:
1×1ml
5×1 ml
1×5 ml
5×5 ml
Matrix Spherical:
Highly cross-linked 6% agarose
Static Binding Capacity:
>10mg 6×His-tagged protein/ml medium
Particle size:
45-165μm
Maximum Pressure:
0.3MPa
3bar
Compatibility:
compatible with akta/fplc column
  • IMAC Ni-NTA 6FF Prepacked Column

Description

IMAC Ni-NTA 6FF Prepacked Column (His)


  1. Product Description

Ni Smart Beads 6FF is a new immobilized metal ion affinity chromatography(IMAC)medium precharged with nickel ions. Ni Smart Beads 6FF is designed mainly for capture and purification of histidine-tagged proteins secreted into eukaryotic cell culture supernatants. The strong nickel ion binding also provides very high resistance to EDTA and reducing agents like DTT. Ni Smart Beads 6FF enable direct loading of large sample volumes without having to remove agents that cause stripping of nickel ions from conventional IMAC medium. Ni Smart Beads 6FF is stable in all buffers commonly used in IMAC.

IMAC Ni-NTA 6FF Prepacked Column is one of a range of prepacked, ready-to-use columns for affinity chromatography. It is prepacked with 1ml and 5ml of Ni Smart Beads 6FF. Five different packing sizes are available. IMAC Ni-NTA 6FF Prepacked Column has the standard interface and can be operated with a peristaltic pump or liquid chromatography systems, such as KTA. It is fast, simple and easy operation.

Table 1. Characteristics of Ni Smart Beads 6FF

Item

Description

Matrix Spherical

Highly cross-linked 6% agarose

Static Binding Capacity

>10mg 6×His-tagged protein/ml medium

Particle size

45-165μm

Maximum Pressure

0.3MPa, 3bar

Storage Solution

1×PBS containing 20% ethanol

Storage Temperature

4-30℃


Table 2. Chemical compatibilities for Ni Smart Beads 6FF

Solution

Time

0.01M HCl ,0.01M NaOH

One week

10mM EDTA, 1M NaOH,

5mM DTT, 5mM TCEP,

20mM β-mercaptoethanol,

6M guanidine-HCl

24 hours

500mM imidazole,

100mM EDTA

2 hours

30% isopropanol

20 minutes

  1. Purification Procedure

2.1 Buffer Preparation

Water and chemicals used for buffer preparation should be of high purity. It is recommended filtering the buffers by passing them through a 0.22μm or 0.45 μm filter before use.

Binding Buffer:20mM sodium phosphate,0.5M NaCl, pH7.4

Wash Buffer: 20mM sodium phosphate, 0.5M NaCl, 0-5mM imidazole, pH7.4

Elution Buffer: 20mM sodium phosphate, 0.5M NaCl, 250mM imidazole, pH7.4

Note: 1) It is not recommended to include imidazole in sample and equilibration buffers. To minimize host cell proteins in the eluate, it is recommended to include imidazole at low concentrations in the wash buffer . However ,for some target proteins, even a small increase of the imidazole concentration in the wash buffer may lead to partial elution.

2) Addition of salt, for example 0.5 to 1.0 M NaCl in buffers eliminates ion-exchange effects.

3) Alternatively, the proteins may be eluted by other methods or combinations of methods, for example by lowering pH within the range 2.5 to 5.0.

2.2 Sample Preparation

1) Before sample loading, remove the cell by centrifugation at 7,000rpm(7,500×g) for 10-15min at 4℃, otherwise clogging of the column may occur.

2) For optimal binding, it is not recommended to include imidazole in sample and equilibration buffer.

3) It is not be pretreatment when the samples solution contain the tolerance reagent and low target protein concentration.

2.3 Sample Purification

IMAC Ni-NTA 6FF Prepacked Column is a prepacked, ready to use column for purification of 6X His-tagged proteins. The prepacked column provides fast, simple and easy separations in a convenient format.

1) Fill the syringe or pump tubing with binding buffer. Remove the stopper and connect the column to the syringe (with the provided connector), or pump tubing, “drop to drop” to avoid introducing air into the column. Remove the snap-off end at the column outlet.

2) Wash the column with 10 column volumes of binding buffer at 1 ml/min or 5 ml/min for 1 ml and 5 ml column respectively.

3) Apply the sample, using a syringe fitted to the connector or by pumping it onto the column.

4) Wash with 5 to 10 column volumes of binding buffer or until no material appears in the effluent.

5) Elute with 5 column volumes of elution buffer. Other volumes may be required if the interaction is difficult to break.

2.4 Analysis

Identify the fractions containing the His-tagged protein. Use UV absorbance, SDS-PAGE, or western blot.

  1. Cleaning-in-Place

A column used to purify protein from cell extract usually contains some soluble substances and cell debris that are nonspecifically absorbed onto the matrix. Cleaning-in-Place eliminates material not removed by regeneration and prevents progressive buildup of contaminants. If the column is to be reused, these contaminants should be cleaned from the column, as they were not completely removed during the sample clarification steps.

Remove the strong hydrophobic binding protein, lipoprotein and lipid

Wash the column using 5-10 column volumes 30% isopropanol contacting for 15-20min. Or you can choose the 2CV acidic or alkaline solution containing detergents, for example, 0.1 M acetic acid solution contains 0.1-0.5% non-ionic detergent, contacting for 1-2 hours .

Finally wash the column with 10CV distilled water

Remove the proteins combined with ion interacting

Wash the column with 1.5M NaCl solution contacting for 10-15min.

Finally wash the column with 10 column volumes distilled water

  1. Troubleshooting

Problem

Probable cause

Solution

Back pressure exceeds 3 bar

Column is clogged

Cleaning in place (Part 3).

Increase the centrifugation speed or filtering the sample.

No protein is eluted

Expression of target protein in extract is very low

Check expression level of protein by estimating the amount in the extract, flow through, elute fraction and pellet upon centrifugation. Or apply large sample volume.

Target protein is found in the flow through

Reduce imidazole concentration in equilibration buffer sample and wash buffer. Increase buffer pH.

Elution conditions are too mild.

Increase imidazole concentration in elution buffer. Or decrease buffer pH.

Protein degradation or purification cause the his-tag to be removed.

Operate at 4°C. Add protease inhibitors.

Make a new construct with his-tag attached to other terminus.

His-tagged protein is not pure

Wash is not enough

Increase the volume of wash buffer.

His-tagged protein is not pure

Association between the his-tagged protein and protein contaminant.

Optimize the wash condition by adjusting the pH and imidazole concentration.

Add an additional chromatography step, that is ion exchange, hydrophobic interaction or size exclusion.

Protein precipitates during purification

Temperature is too low

Perform the purification at room temperature.

Aggregate formation

Add solubilization agents to the samples and buffers, for example 0.1% Triton X-100 , Tween-20 and ≤20% glycerol to maintain protein solubility.