Octyl Beads 4FF
Octyl Beads 4FF are media for Hydrophobic Interaction Chromatography(HIC). Substances are separated on the basis of their varying strength of their hydrophobic interaction with hydrophobic groups attached to the uncharged matrix. They are developed and supported for process scale chromatography. The base matrix of Octyl Beads 4FF is highly cross-linked agarose. They have high chemical and physical stability. Details see table under each respective HIC media.
Octyl Beads 4FF is aliphatic hydrophobic Interaction medium. The octyl group is coupled to beads by ether linkage, giving a hydrophobic medium with minimal leakage and no ionic properties.
Table . Characteristics of Octyl Beads 4FF
Item | Description |
Matrix | Highly cross-linked 4% agarose |
Type of ligand | Octyl |
Capacity (/ml medium ) | approx.26 mg lgG, >7 mg BSA |
Particle Size (μm) | 45-165 |
Flow rate | 300 cm/h |
pH stability | 3-13 |
Storage buffer | 20% ethanol |
Storage | 4℃ - 30℃ |
2.1 Buffer Preparation
Water and chemicals used for buffer preparation should be high purity. It is recommended to filter the buffers by passing them through a 0.22μm or 0.45μm filter before use.
Binding/wash buffer: 0.05 M phosphate, 1.7 M (NH4)2SO4, pH7.0
Elution Buffer: 0.05 M phosphate, pH7.0
Note: The buffer of HIC can be changed according to different samples and the medium.The salt concentration of buffer is high in Binding/wash buffer and low in elution buffer.
2.2 Sample Preparation
It is recommended to filter the sample solution by passing them through a 0.22 μm or 0.45 μm filter before use.
The salt concentration in the sample is the same as binding /wash buffer. It is usually 0.5-2.0 M (NH4)2SO4.
2.3 Packing Columns
1) Remove air from the column dead spaces by flushing the end-piece and adapter with packing buffer. Make sure no air has been trapped under the column net.
2) Close the column outlet leaving the net covered with packing buffer.
3) Resuspend the beads stored in its container by shaking (avoid stirring the sedimented medium). Pouring the slurry down a glass rod held against the column wall will minimize the introduction of air bubbles.
If using a packing reservoir, immediately fill the remainder of the column and reservoir with packing buffer. Mount the adapter or lid of the packing reservoir and connect the column to a pump. Avoid trapping air bubbles under the adapter or in the inlet tubing.
5) Maintain packing flow velocity for at least 3 bed volumes. When the bed has stabilized, mark the bed height on the column and close the bottom outlet and stop the pump.
If using a packing reservoir, disconnect the reservoir and fit the adapter to the column. If using the column, carefully place the top filter on top of the bed before fitting the adapter.
flush the adapter inlet. Lock the adapter in position.
8) Close the bottom outlet. Disconnect the column inlet and lower the adapter approximately 2 mm into the bed. Connect the pump. The column is now ready to use.
2.4 Sample Purification
1) Fill the syringe or pump tubing with binding buffer. Remove the stopper and connect the column to the syringe (with the provided connector), or pump tubing, “drop to drop” to avoid introducing air into the column. Remove the snap-off end at the column outlet.
2) Wash the column with 10 column volumes of binding buffer.
3) Apply the sample, using a syringe fitted to the connector or by pumping it onto the column.
Note:Hydrophobic interaction is weaker at lower temperatures. This must be taken into account if chromatography is done in a cold room.
4) Wash with 5 to 10 column volumes of binding buffer or until no material appears in the effluent.
5) Elute with Elution Buffer using a stepwise or linear gradient. For one-step elution, 5 column volumes are usually enough. Other volumes may be required if the interaction is difficult to break. Linear gradient elution can be used to separate proteins of different binding strengths with a small gradient, such as 20 column volumes or more.
2.5 Analysis
Identify the fractions containing the target protein. using UV absorbance, SDS-PAGE, or western blot.
After each separation, elute reversibly bound material with low ionic strength buffer. Wash the column wit 5 column volumes of distilled water and 30%isopropanol.
Wash the column with 3 column volumes of 70% ethanol or 30% isopropanol (apply increasing concentration gradients to avoid air bubbles formation) . Alternatively, wash the column with 3 column volumes of 0.1-0.5% detergent in a basic or acidic solution. For example, wash with 0.1-0.5% non-ionic detergent in 0.1 M acetic acid .Contact time 1-2 h.
Wash the column with distilled water and re-equilibrate.
Wash the column with 1 M NaOH. Contact time 30-60 min.
Wash the column with distilled water and re-equilibrate.
Product | Cat. No. | Size |
Butyl Beads 4FF | SH001025 SH001100 SH001500 SH00101L | 25 ml 100 ml 500 ml 1 L |
Octyl Beads 4FF | SH003025 SH003100 SH003500 SH00301L | 25 ml 100 ml 500 ml 1 L |
Phenyl Beads 6FF (Low Sub) | SH004025 SH004100 SH004500 SH00401L | 25 ml 100 ml 500 ml 1 L |
Phenyl Beads 6FF (High Sub) | SH006025 SH006100 SH006500 SH00601L | 25 ml 100 ml 500 ml 1 L |